CKT1175-15

High Voltage Test System

Stimulus / Measurement Units

Continuity Testing
  • 12.5 mV – 50 VDC
  • 100µA – 2A
  • Resistance meas. as low as 1mΩ

Insulation Resistance Testing
  • 12.5 mV – 2000 VDC
  • IR measurements to 5000 megohms
  • Hipot testing
  • Dwell time prog. from 1 ms to 1000s in 1 ms steps

AC/DC/I Measurements
  • 0.375-1500 VAC RMS
  • Test voltage ramp: 500V/0.1S, 500V/S, 500V/10S

AC Dielectric Testing
  • Voltage ranges – 0.375VAC – 1500VAC
  • Current ranges – 10µA to 100mA

Instrument Specifications

Continuity Test

TEST CURRENT
Full Scale Range Programmable Steps Accuracy
0.010 Amps 2.5µA ± 2%
0.100 Amps 25µA ± 2%
1.000 Amp 250µA ± 2%
10.000 Amps 2.5mA ± 2%
4-WIRE RESISTANCE RANGES
Current Range Measurement Range Accuracy
1 A – 2 A 0.01 ohm – 0.1 ohm ± 1 mohm
2 A – 5 A (pulsed) 0.01 ohm – 0.1 ohm ± 1 mohm
100 mA – 2 A 0.1 ohm – 1 ohm ± 1 mohm
2 A – 5 A (pulsed) 0.1 ohm – 1 ohm ± 1 mohm
100 mA – 2 A 1 ohm – 10 ohms ± 0.5%
2 A – 5 A (pulsed) 1 ohm – 10 ohms ± 0.5%
10 mA – 2 A 10 ohm – 100 ohms ± 0.5%
2 A – 3 A (pulsed) 10 ohm – 100 ohms ± 0.5%
10 mA – 500 mA 100 ohm – 1 Kohms ± 0.5%
1 mA – 50 mA 1 Kohms – 10 Kohms ± 0.5%
CONTINUITY TESTING COMPLIANCE VOLTAGE
Full Scale Range Programmable Steps Accuracy
12.5mVDC – 50.0VDC 12.5mVDC ± 2%
2-WIRE RESISTANCE RANGES
Current Range Measurement Range Accuracy
1 A – 2 A (4-pass mode) 0.1 ohm – 10 ohms ± 0.5%, ± 0.05 ohm*
100 mA – 2 A 1 ohm – 10 ohms ± 0.2 ohm
2 A – 5 A (pulsed) 1 ohm – 10 ohms ± 0.2 ohm
100 mA – 2 A 10 ohm – 100 ohms ± 0.5%, ± 0.2 ohm*
2 A – 3 A (pulsed) 10 ohm – 100 ohms ± 0.5%, ± 0.2 ohm*
10 mA – 500 mA 100 ohm – 1 Kohms ± 1%
1 mA – 50 mA 1 Kohms – 10 Kohms ± 1%
100 uA – 5 mA 10 Kohms – 100 Kohms ± 1.5%
100 uA – 500 uA 100 Kohms – 1 Mohms ± 5%
* whichever is greater

DC Insulation Resistance Test

DC INSULATION RESISTANCE TEST VOLTAGE
Voltage Range Programmable Steps Accuracy
1VDC – 50VDC 12.5mVDC ± 2%
50VDC – 2000VDC 0.025VDC ± 2%
INSULATION RESISTANCE MEASUREMENT
Voltage Range Measurement Range Accuracy
1 VDC – 10 VDC 200 ohms – 10 Mohms ± 3%
10 VDC – 50 VDC 10 Kohms – 100 Mohms ± 3%
50 VDC – 1500 VDC 100 Kohms – 10 Mohms ± 1%
50 VDC – 1500 VDC 10 Mohms – 100 Mohms ± 3%
50 VDC – 1500 VDC 100 Mohms – 1 Gohms ± 25%*

AC Dielectric Breakdown Test

AC DIELECTRIC BREAKDOWN TEST VOLTAGE
Voltage Range Programmable Steps Accuracy
0.375 VAC RMS – 1500 VAC RMS 375 mVAC RMS ± 2%
AC DIELECTRIC BREAKDOWN MEASUREMENT
Voltage Range Measurement Range Accuracy
100VAC RMS – 1500VAC RMS 100µA-5mA ± 10%

Measurements

VOLTAGE MEASUREMENT
Full Scale Range Accuracy
0.1V ± (0.5% ± 0.4 % FS)
1V ± (0.3% ± 0.3 % FS)
10V ± (0.25% ± 0.25% FS)
100V ± (0.25% ± 0.25% FS)
1000V ± (0.25% ± 0.25% FS)
CURRENT MEASUREMENT
Full Scale Range Accuracy
10µA ± (0.4% ± 0.35 % FS)
100µA ± (0.3% ± 0.2 % FS)
1mA ± (0.3% ± 0.2% FS)
10mA ± (0.4% ± 0.2% FS)
100mA ± (0.4% ± 0.2% FS)
DC CAPACITANCE MEASUREMENT
Range Accuracy
10pfd – 1nfd ± 5%, ± 5pfd*
1nfd – 100nfd ± 2.5%
100nfd – 500μfd ± 2.5%
* whichever is greater
AC CAPACITANCE MEASUREMENT
Range Accuracy
10pfd – 1nfd ± 10%, ± 5pfd*
1nfd – 100nfd ± 10%
100nfd – 500μfd ± 10%
* whichever is greater